{"id":6809,"date":"2022-05-31T12:12:18","date_gmt":"2022-05-31T10:12:18","guid":{"rendered":"https:\/\/www.dentalcadmos.com\/?p=6809"},"modified":"2022-05-31T12:12:18","modified_gmt":"2022-05-31T10:12:18","slug":"efficacia-del-sigillo-della-connessione-morse-taper-studio-in-vitro-con-turbidimetria-e-rt-pcr-2","status":"publish","type":"post","link":"https:\/\/www.dentalcadmos.com\/en\/efficacia-del-sigillo-della-connessione-morse-taper-studio-in-vitro-con-turbidimetria-e-rt-pcr-2\/","title":{"rendered":"Efficacia del sigillo della connessione Morse-taper: studio in vitro con turbidimetria e RT-PCR"},"content":{"rendered":"<p style=\"text-align: justify;\"><strong>OBIETTIVI:<\/strong> La colonizzazione microbica dell\u2019interfaccia impianto-abutment (implant-abutment interface-IAI) dovuta a un incongruo accoppiamento delle sue componenti pu\u00f2 provocare infiammazione dei tessuti perimplantari, predisponendo all\u2019insorgenza di patologie come mucosite perimplantare e perimplantite.<br \/>\nUno scorretto assemblaggio delle componenti implantari pu\u00f2 comportare la presenza di un microgap a livello della IAI, all\u2019interno del quale i microrganismi migrano e proliferano.<br \/>\nTuttavia, a differenza di altri tipi di connessione, la connessione frizionale tipica del design Morsetaper garantisce uno spazio ridotto tra impianto e moncone e maggiore resistenza ai carichi funzionali, favorendo il sigillo microbiologico sia in condizioni statiche che dinamiche.<br \/>\nQuesto studio ha lo scopo di valutare le infiltrazioni batteriche a livello delle connessioni Morse-taper tramite tre test differenti validati dalla letteratura esistente: la turbidimetria, la PCR real-time e l\u2019elettroforesi orizzontale.<\/p>\n<p style=\"text-align: justify;\"><strong>MATERIALI E METODI:<\/strong> Una sospensione batterica contenente una miscela di tre specie batteriche (A. actinomycetemcomitans, F. nucleatum e P. gingivalis) \u00e8 stata inoculata nella cavit\u00e0 interna di dieci campioni formati da impianto e moncone con connessione Morse-taper a eccezione di uno, usato come controllo negativo.<br \/>\nI campioni sono stati assemblati tramite un percussore calibrato con una forza standardizzata di 15 N e posizionati singolarmente in provette sterili in cui si trovavano completamente immersi all\u2019interno del liquido di coltura, ottenuto unendo il terreno di coltura delle specie batteriche a un mezzo liquido. I campioni sono stati successivamente incubati a 37 \u00b0C in atmosfera anaerobica.<br \/>\nA 24, 48 e 72 ore sono state effettuate le analisi di torbidit\u00e0, la PCR real-time e l\u2019elettroforesi orizzontale per rilevare l\u2019entit\u00e0 dell\u2019infiltrazione microbiologica a livello della connessione tra impianto e moncone. Tutte le procedure sono state effettuate in condizioni sterili.<\/p>\n<p style=\"text-align: justify;\"><strong>RISULTATI E CONCLUSIONI:<\/strong> Tutti i test sono risultati negativi a eccezione di due campioni, dovuti per\u00f2 alla contaminazione esterna durante la manipolazione dei componenti. Nonostante secondo la letteratura nessuna connessione garantisca un sigillo microbiologico completo, la connessione Morse-taper ha dimostrato una minore infiltrazione microbiologica<br \/>\nrispetto ad altri design.<br \/>\nInoltre, alcuni studi hanno riportato che tale tipo di connessione \u00e8 associata a un minore riassorbimento osseo, sebbene non sia chiaro se per questioni microbiologiche o meccaniche.<br \/>\nMalgrado le limitazioni dovute all\u2019impostazione dello studio e ad altri fattori di natura operativa, tale valutazione in vitro dimostra la capacit\u00e0 di sigillo delle connessioni Morse-taper in condizioni statiche rispetto ad altri design, confermando i risultati ottenuti in altri studi simili precedentemente pubblicati.<\/p>\n<p style=\"text-align: justify;\"><strong>SIGNIFICATO CLINICO:<\/strong> Oltre ai gi\u00e0 dimostrati vantaggi tecnici e meccanici della connessione implantare Morse-taper, la sua capacit\u00e0 di sigillo contro la micro-infiltrazione batterica, che \u00e8 stata confermata nel presente studio in vitro attraverso tre metodi validati dalla letteratura, potrebbe prevenire la colonizzazione batterica a livello della IAI. Di conseguenza, tale connessione potrebbe salvaguardare maggiormente la salute dei tessuti perimplantari, prevenendo le patologie infiammatorie. Sono comunque necessari ulteriori valutazioni con un maggiore numero di campioni e in condizioni dinamiche per confermare i risultati e le conclusioni riportati.<\/p>\n<p><i>Per continuare la lettura gli abbonati possono scaricare l\u2019allegato.<\/i><\/p>\n","protected":false},"excerpt":{"rendered":"<p>OBIETTIVI: La colonizzazione microbica dell\u2019interfaccia impianto-abutment (implant-abutment interface-IAI) dovuta a un incongruo accoppiamento delle sue componenti pu\u00f2 provocare infiammazione dei tessuti perimplantari, predisponendo all\u2019insorgenza di patologie come mucosite perimplantare e perimplantite. Uno scorretto assemblaggio delle componenti implantari pu\u00f2 comportare la presenza di un microgap a livello della IAI, all\u2019interno del quale i microrganismi migrano e &hellip; <a href=\"https:\/\/www.dentalcadmos.com\/en\/efficacia-del-sigillo-della-connessione-morse-taper-studio-in-vitro-con-turbidimetria-e-rt-pcr-2\/\">Continued<\/a><\/p>\n","protected":false},"author":2,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[1],"tags":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v17.4 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Efficacia del sigillo della connessione Morse-taper: studio in vitro con turbidimetria e RT-PCR - Dental Cadmos<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.dentalcadmos.com\/en\/efficacia-del-sigillo-della-connessione-morse-taper-studio-in-vitro-con-turbidimetria-e-rt-pcr-2\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Efficacia del sigillo della connessione Morse-taper: studio in vitro con turbidimetria e RT-PCR - Dental Cadmos\" \/>\n<meta property=\"og:description\" content=\"OBIETTIVI: La colonizzazione microbica dell\u2019interfaccia impianto-abutment (implant-abutment interface-IAI) dovuta a un incongruo accoppiamento delle sue componenti pu\u00f2 provocare infiammazione dei tessuti perimplantari, predisponendo all\u2019insorgenza di patologie come mucosite perimplantare e perimplantite. Uno scorretto assemblaggio delle componenti implantari pu\u00f2 comportare la presenza di un microgap a livello della IAI, all\u2019interno del quale i microrganismi migrano e &hellip; Continued\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.dentalcadmos.com\/efficacia-del-sigillo-della-connessione-morse-taper-studio-in-vitro-con-turbidimetria-e-rt-pcr-2\/\" \/>\n<meta property=\"og:site_name\" content=\"Dental Cadmos\" \/>\n<meta property=\"article:published_time\" content=\"2022-05-31T10:12:18+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"edra\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.dentalcadmos.com\/#website\",\"url\":\"https:\/\/www.dentalcadmos.com\/\",\"name\":\"Dental Cadmos\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.dentalcadmos.com\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.dentalcadmos.com\/efficacia-del-sigillo-della-connessione-morse-taper-studio-in-vitro-con-turbidimetria-e-rt-pcr-2\/#webpage\",\"url\":\"https:\/\/www.dentalcadmos.com\/efficacia-del-sigillo-della-connessione-morse-taper-studio-in-vitro-con-turbidimetria-e-rt-pcr-2\/\",\"name\":\"Efficacia del sigillo della connessione Morse-taper: studio in vitro con turbidimetria e RT-PCR - Dental Cadmos\",\"isPartOf\":{\"@id\":\"https:\/\/www.dentalcadmos.com\/#website\"},\"datePublished\":\"2022-05-31T10:12:18+00:00\",\"dateModified\":\"2022-05-31T10:12:18+00:00\",\"author\":{\"@id\":\"https:\/\/www.dentalcadmos.com\/#\/schema\/person\/dae8bc45e635361a55553f0aac0857fe\"},\"breadcrumb\":{\"@id\":\"https:\/\/www.dentalcadmos.com\/efficacia-del-sigillo-della-connessione-morse-taper-studio-in-vitro-con-turbidimetria-e-rt-pcr-2\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.dentalcadmos.com\/efficacia-del-sigillo-della-connessione-morse-taper-studio-in-vitro-con-turbidimetria-e-rt-pcr-2\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.dentalcadmos.com\/efficacia-del-sigillo-della-connessione-morse-taper-studio-in-vitro-con-turbidimetria-e-rt-pcr-2\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.dentalcadmos.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Efficacia del sigillo della connessione Morse-taper: studio in vitro con turbidimetria e RT-PCR\"}]},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.dentalcadmos.com\/#\/schema\/person\/dae8bc45e635361a55553f0aac0857fe\",\"name\":\"edra\",\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/www.dentalcadmos.com\/#personlogo\",\"inLanguage\":\"en-US\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/e2aad0a8340bb6125c47d6b52ca5828e?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/e2aad0a8340bb6125c47d6b52ca5828e?s=96&d=mm&r=g\",\"caption\":\"edra\"},\"url\":\"https:\/\/www.dentalcadmos.com\/en\/author\/edra\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Efficacia del sigillo della connessione Morse-taper: studio in vitro con turbidimetria e RT-PCR - Dental Cadmos","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.dentalcadmos.com\/en\/efficacia-del-sigillo-della-connessione-morse-taper-studio-in-vitro-con-turbidimetria-e-rt-pcr-2\/","og_locale":"en_US","og_type":"article","og_title":"Efficacia del sigillo della connessione Morse-taper: studio in vitro con turbidimetria e RT-PCR - Dental Cadmos","og_description":"OBIETTIVI: La colonizzazione microbica dell\u2019interfaccia impianto-abutment (implant-abutment interface-IAI) dovuta a un incongruo accoppiamento delle sue componenti pu\u00f2 provocare infiammazione dei tessuti perimplantari, predisponendo all\u2019insorgenza di patologie come mucosite perimplantare e perimplantite. Uno scorretto assemblaggio delle componenti implantari pu\u00f2 comportare la presenza di un microgap a livello della IAI, all\u2019interno del quale i microrganismi migrano e &hellip; Continued","og_url":"https:\/\/www.dentalcadmos.com\/efficacia-del-sigillo-della-connessione-morse-taper-studio-in-vitro-con-turbidimetria-e-rt-pcr-2\/","og_site_name":"Dental Cadmos","article_published_time":"2022-05-31T10:12:18+00:00","twitter_card":"summary_large_image","twitter_misc":{"Written by":"edra","Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebSite","@id":"https:\/\/www.dentalcadmos.com\/#website","url":"https:\/\/www.dentalcadmos.com\/","name":"Dental Cadmos","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.dentalcadmos.com\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/www.dentalcadmos.com\/efficacia-del-sigillo-della-connessione-morse-taper-studio-in-vitro-con-turbidimetria-e-rt-pcr-2\/#webpage","url":"https:\/\/www.dentalcadmos.com\/efficacia-del-sigillo-della-connessione-morse-taper-studio-in-vitro-con-turbidimetria-e-rt-pcr-2\/","name":"Efficacia del sigillo della connessione Morse-taper: studio in vitro con turbidimetria e RT-PCR - Dental Cadmos","isPartOf":{"@id":"https:\/\/www.dentalcadmos.com\/#website"},"datePublished":"2022-05-31T10:12:18+00:00","dateModified":"2022-05-31T10:12:18+00:00","author":{"@id":"https:\/\/www.dentalcadmos.com\/#\/schema\/person\/dae8bc45e635361a55553f0aac0857fe"},"breadcrumb":{"@id":"https:\/\/www.dentalcadmos.com\/efficacia-del-sigillo-della-connessione-morse-taper-studio-in-vitro-con-turbidimetria-e-rt-pcr-2\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.dentalcadmos.com\/efficacia-del-sigillo-della-connessione-morse-taper-studio-in-vitro-con-turbidimetria-e-rt-pcr-2\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.dentalcadmos.com\/efficacia-del-sigillo-della-connessione-morse-taper-studio-in-vitro-con-turbidimetria-e-rt-pcr-2\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.dentalcadmos.com\/"},{"@type":"ListItem","position":2,"name":"Efficacia del sigillo della connessione Morse-taper: studio in vitro con turbidimetria e RT-PCR"}]},{"@type":"Person","@id":"https:\/\/www.dentalcadmos.com\/#\/schema\/person\/dae8bc45e635361a55553f0aac0857fe","name":"edra","image":{"@type":"ImageObject","@id":"https:\/\/www.dentalcadmos.com\/#personlogo","inLanguage":"en-US","url":"https:\/\/secure.gravatar.com\/avatar\/e2aad0a8340bb6125c47d6b52ca5828e?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/e2aad0a8340bb6125c47d6b52ca5828e?s=96&d=mm&r=g","caption":"edra"},"url":"https:\/\/www.dentalcadmos.com\/en\/author\/edra\/"}]}},"_links":{"self":[{"href":"https:\/\/www.dentalcadmos.com\/en\/wp-json\/wp\/v2\/posts\/6809"}],"collection":[{"href":"https:\/\/www.dentalcadmos.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.dentalcadmos.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.dentalcadmos.com\/en\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.dentalcadmos.com\/en\/wp-json\/wp\/v2\/comments?post=6809"}],"version-history":[{"count":1,"href":"https:\/\/www.dentalcadmos.com\/en\/wp-json\/wp\/v2\/posts\/6809\/revisions"}],"predecessor-version":[{"id":6812,"href":"https:\/\/www.dentalcadmos.com\/en\/wp-json\/wp\/v2\/posts\/6809\/revisions\/6812"}],"wp:attachment":[{"href":"https:\/\/www.dentalcadmos.com\/en\/wp-json\/wp\/v2\/media?parent=6809"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.dentalcadmos.com\/en\/wp-json\/wp\/v2\/categories?post=6809"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.dentalcadmos.com\/en\/wp-json\/wp\/v2\/tags?post=6809"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}